CONTROL GEAR FOR HIGH PRESSURE DISCHARGE LAMPS –
IGNITORS The digital gears for disturbance free use.
At the
end of lamp life Metal Halide and High Pressure Sodium lamps will
inevitably cause RFI. The lamp burns for a minute and then switches off,
until the lamp fails fully or is changed. Tridonic time ignitors cure this
problem by turning off after 2 or 3 failed lamp ignition
cycles.
The older timed ignitors switched off the lamps after a
defined time period. These ignitors could not consider the re-ignition
times due to the lamp temperature. For every lamp type there has been a
special ignitor required.
The solution: The
ASIC-PulseControl does not rely on the re-ignition phases, but
measures the re-ignition attempts independent of lamp temperature and
type. The ignitor will automatically switch off after 3 failed attempts.
Therefore only one ignitor is required for all lamp types.
|
|
 |